Sadelco Inc.®    Signal Level Meters
75 W. Forest Ave, Englewood, NJ  07631
Tel: 201-569-3323   800-569-6299  Fax: 201-569-6285   Email: sales@sadelco.com        Sadelco Home Page

 
        

Frequency Range: 5-872 MHz		Tilt					 				                             
Accuracy: + 20 KHz                     	Automatically calculated from user
Resolution: 125KHz                      selected carriers.              
IF Bandwidth: 280KHz                           
                    		        Audio                         
Level Measurement                       Adjustable volume, waterproof
Range:  -30 + 60 dBmV                   mylar speaker.
Accuracy: + 1.0 dB at 77° F                              
+ 2.0 dB Total (0° - 120° F)            General Dimensions                                   
Resolution:  0.1 dB			4.25" x 10" x 2.75"	                                             
                        		11 cm x 25.5 cm x 7cm
Ingress Sweep	                    	Weight: 3 lbs (1.4Kg) including 
Sweeps Sub Band in 250 KHz steps.      	case & batteries.      
                                	  
Digital Channel Measurement	        Operating Temp: 0° - 120° F                                       
Average Power Accuracy:			(-18° to 49°C)		                               
+ 1.8 dB at 77° F		      	Storage Temp: -4° to 140° F                    
+ 2.8 dB Total (0° - 120° F)	        (-20° to 60° C)
Type:  QAM,QPSK,VSB and QPR                       		    
				        Battery                 
Auto Calibration		        Type: 6 Sub C Cells 	
Noise Source Stability:                 Charge Time: 4 Hours
0.2 dB 0° - 120° F             		Battery Life: 4 hours Continuous
Measurements corrected for power	(backlight off)
level, frequency and temperature.       Electronic Shut-Off: Saves power
			            	extends operating time
Automated Testing			    
Scan Rate: 6 Carriers/sec		Standard Channel Plans     
Storage: >40 Scans of 135		NTSC, HRC, IRC, AIR (VHF,UHF), PAL,
Channels each.   	            	Custom plans available on request.
               				
C/N		                	Accessories Supplied             
Range: 50dB		                Padded Nylon Case: Part# CASE005
Accuracy: + 2.0 dB at 77° F             110 Volt AC Charger: Part# T70
(+ 3.0 dB 0° - 120° F)			Nicad Battery Pack: Part# BAT07
					12 V Car Charger Cable: Part# CH04
Hum                         	        Operator's Manual: Part# ST1008
Range: 0 - 5%	                     	
Filter: 20 - 200 Hz         		Optional Accessories
				       	StrandHook/Handle: Part# SH2
		   	                PC Download Cable: Part# CA10
                                        Clone Cable: Part# CA20
                                	220/240 Volt AC Charger: Part# T70E
	                   						                         	
		                        Specifications Subject to change without notice.